Probably the highest-located building with Lignotrend elements is the four-storey, energetically self-sufficient Refuge du Goûter on the Montblanc massif. The timber components were used here because they gua-rantee optimum load-bearing capacity and the best sound insulation with comparatively low weight: After all, they could only be flown to the construc-tion site by helicopter. While the gigantic mountain hut is clad with stainless steel sheeting on the outside, spruce timber dominates the interior.  

Configuration overview

Components used

  • LIGNO® Rippe Q3  |  Ceiling component

    Product code: LIGNO® Rippe Q3_150-210_r0_s0_z53_p0_a50g_625-23-8_FI-ä_gb_b0
    Installation top


    Whether the element is open or closed at the top is determined by the area of application. If, for example, the element is to be filled with fill on site as a storey ceiling or roof terrace (LIGNO® Rippe Q3-x), its cavities are open at the top (feature _r0). To guide pipes at the top of the element, a cross grid (_r25, _r50) can be added to some superstructures. For roof superstructures, there is usually a flat closed finish _rg0 (LIGNO® Block Q-x, LIGNO® Block Q3-x or corresponding versions of LIGNO® Acoustic classic).

    Installation top

    _r0 Open, without cross grid

    Statics


    The height of the load-bearing webs of the element is variable and determined according to static requirements from load and span. Within the framework of this configurator, the selection is limited to four height ranges. A more precise definition is made later during pre-dimensioning or verification with the LTB-x calculation programme. Bulk volume and/or necessary space for installations can also be decisive for the height.

    Statics

    _150-210 Small span

    Fire resistance


    If fire protection is required, an additional layer is added below the web area (for elements with strip profiles _z26, _z53, _z80, for elements with board profiles Akustik klassik _k50g). Their height determines the fire resistance duration of the cross-section from 30 to 90 minutes. The fire resistance must be statically verified. If there are no requirements, the standard versions _z0 or _k50l are to be selected.

    Fire resistance

    _z53 REI 60 High fire resistance

    Cavity


    Panel designs with slat profiles and additional layer can be configured with an additional cavity (_p26, _p53) below the additional layer for installation guides, fixtures or to improve sound absorption. Cables laid there then do not penetrate the fire-protection layer. If required, the cavity is filled with insulating material (_p26mw, _p26ha) to improve acoustic absorption. If no cavity is necessary, the characteristic _p0 is selected. 

    Cavity

    _p0 No cavity

    Room acoustics


    If the soffit of the element is to have a good sound-absorbing effect, the penultimate layer is configured as absorber _a50g. Otherwise, this layer is configured as a solid wood layer _a0.

    Room acoustics

    _a50g Integrated absorber 

    Profile


    The visible layer is profiled with joints. The code for profiling indicates in millimetres: Element width, strip width (rounded, from/to if applicable) and joint width (rounded) as well as a letter identification for variants, e.g. with chamfered strip edges or with additional height gradation. 

    Note: Some profiles indirectly cause exclusions for other configuration options.

    Profile 

    _625-23-8 Slat profile

    Wood type


    Various wood species are available for the visible layer. For quality reasons, individual wood species cannot be configured for all profiles; for technical reasons, surface treatments are excluded for some wood species.

    Wood type

    _FI-ä Spruce with knots, A quality

    Treatment


    Depending on the type of wood, the optional application of a surface treatment is possible ex works. Individual colour finishes are always sampled for coordination. For elements in individual lengths, colour treatment is limited to max. 5 m length.

    Treatment

    _b0 Untreated

    Structure


    The face is subjected to a brushing _gb as standard, which produces a stronger or weaker structure depending on the type of wood and makes the surface less sensitive to scratches.  Alternatively, a smooth sanding _gs can be carried out, or on request a bandsaw cut _grimitated.

    Structure

    _gb Brushed

  • LIGNO® Rippe Q3  |  Ceiling component

    Product code: LIGNO® Rippe Q3_150-210_r0_s0_z26_p0_a0_625-618-7_FI-ä_gb_b0
    Installation top


    Whether the element is open or closed at the top is determined by the area of application. If, for example, the element is to be filled with fill on site as a storey ceiling or roof terrace (LIGNO® Rippe Q3-x), its cavities are open at the top (feature _r0). To guide pipes at the top of the element, a cross grid (_r25, _r50) can be added to some superstructures. For roof superstructures, there is usually a flat closed finish _rg0 (LIGNO® Block Q-x, LIGNO Block Q3-x or corresponding versions of LIGNO® Acoustic classic).

    Installation top

    _r0 Open, without cross grid

    Statics


    The height of the load-bearing webs of the element is variable and determined according to static requirements from load and span. Within the framework of this configurator, the selection is limited to four height ranges. A more precise definition is made later during pre-dimensioning or verification with the LTB-x calculation programme. Bulk volume and/or necessary space for installations can also be decisive for the height.

    Statics

    _150-210 Small span

    Fire resistance


    If fire protection is required, an additional layer is added below the web area (for elements with strip profiles _z26, _z53, _z80, for elements with board profiles Akustik klassik _k50g). Their height determines the fire resistance duration of the cross-section from 30 to 90 minutes. The fire resistance must be statically verified. If there are no requirements, the standard versions _z0 or _k50l are to be selected.

    Fire resistance

    _z26 REI 30 Fire resistance

    Cavity


    Panel designs with slat profiles and additional layer can be configured with an additional cavity (_p26, _p53) below the additional layer for installation guides, fixtures or to improve sound absorption. Cables laid there then do not penetrate the fire-protection layer. If required, the cavity is filled with insulating material (_p26mw, _p26ha) to improve acoustic absorption. If no cavity is necessary, the characteristic _p0 is selected. 

    Cavity

    _p0 No cavity

    Room acoustics


    If the soffit of the element is to have a good sound-absorbing effect, the penultimate layer is configured as absorber _a50g. Otherwise, this layer is configured as a solid wood layer _a0.

    Room acoustics

    _a0 Without absorber

    Profile


    The visible layer is profiled with joints. The code for profiling indicates in millimetres: Element width, strip width (rounded, from/to if applicable) and joint width (rounded) as well as a letter identification for variants, e.g. with chamfered strip edges or with additional height gradation. 

    Note: Some profiles indirectly cause exclusions for other configuration options.

    Profile 

    _625-618-7 Closed surface

    Wood type


    Various wood species are available for the visible layer. For quality reasons, individual wood species cannot be configured for all profiles; for technical reasons, surface treatments are excluded for some wood species.

    Wood type

    _FI-ä Spruce with knots, A-quality

    Treatment


    Depending on the type of wood, the optional application of a surface treatment is possible ex works. Individual colour finishes are always sampled for coordination. For elements in individual lengths, colour treatment is limited to max. 5 m length.

    Treatment

    _b0 Untreated

    Structure


    The face is subjected to a brushing _gb as standard, which produces a stronger or weaker structure depending on the type of wood and makes the surface less sensitive to scratches.  Alternatively, a smooth sanding _gs can be carried out, or on request a bandsaw cut _grimitated.

    Structure

    _gb Brushed

Reference-related

Downloads

Project participants

  • Groupe H Architecture & Ingéniere SA

    Architect

    Chemin du Grand-Puits 42
    CH - 1217 Meyrin
     

    www.groupe-h.com

  • DécaLaage - Christophe de Laage

    Architect

    130 Rue Joseph Vallot
    FR - 74400 Chamonix-Mont-Blanc

  • Charpente Concept

    Engineer

    Rue de Valois 8
    FR - 75001 Paris

     

    www.charpente-concept.com

  • Labat et Sierra 

    Execution

    223 Route de la Croix Blanche
    FR - 74330 Sillingy

    www.labat-et-sierra.com

  • Lucien Fortunati photographe

    Photographer

    9 Impasse des Pommiers
    FR - 74330 Epagny Metz-Tessy

     

    www.fortunati.fr

  • Related references

      Umbrüggler Alm 

      The excursion restaurant, which has won several architecture awards and a climate protection prize, stands in the midst of grandiose...

      6020 AT-Innsbruck 

      View
        titletitle

      Nature Experience Hotel "Höchsten"

      The Höchsten mountain inn has been attracting visitors to the Wuerttemberg lookout mountain for decades....

      88636 Illmensee 

      View
        titletitletitletitletitletitletitletitletitletitletitletitle